13.1. Conditioner
Conditioner cooling system
And – area of low pressure
In – area of high pressure 1. Throttle ring consolidation: internal diameter is 9.3 mm thickness is 1.8 mm inhaling moment: 10.0 N of m. 3. Valve of high pressure 4. Switch of high pressure of coolant color of the case: yellow or green working pressure: it is closed: 13.1–17.5 bar opens: 10.6–15.0 bar ring consolidation: internal diameter is 9.3 mm thickness is 1.8 mm inhaling moment: 10.0 N of m. 5. Switch of high pressure of the conditioner (5 cylinder engine) red case opens: 28.2 bar-31.0 of bars it is closed: 10.3 bar-17.3 of bars ring consolidation: internal diameter is 9.3 mm thickness is 1.8 mm inhaling moment: 10.0 N of m. 6. The serving valve of high pressure (the 5-cylinder engine) treats the switch of high pressure of the conditioner it is used for descent and charging of the cooling system of the conditioner 7. Condenser ring consolidation on an entrance: internal diameter is 14.0 mm thickness is 1.8 mm ring consolidation at the exit: internal diameter is 7.5 mm thickness is 1.8 mm the inhaling moment on an entrance: 26.5 N of m. the inhaling moment at the exit: 16.5 N of m. 8. Switch of high pressure of the conditioner (4-cylinder engine) 9. The serving valve of high pressure (the 4-cylinder engine) treats the switch of high pressure of the conditioner it is used for descent and charging of the cooling system of the conditioner |
10. Conditioner compressor ring consolidation of connection with the line of low pressure: internal diameter is 17.2 mm thickness is 1.8 mm ring consolidation of connection with the line of high pressure: internal diameter is 14.0 mm thickness is 1.8 mm moment of an inhaling of connection with the line of low pressure: 42 N. of m. moment of an inhaling of connection with the line of high pressure: 26.5 N of m. 11. Conditioner compressor coupling 12. The serving valve of low pressure it is used for descent and charging of the cooling system 13. Cap 14. Store ring consolidation on an entrance: internal diameter is 17.2 mm thickness is 1.8 mm at the exit: internal diameter is 17.2 mm thickness is 1.8 mm the inhaling moment on an entrance: 42.0 N of m. at the exit: 42.0 N of m. 15. Switch of low pressure of coolant of the conditioner working pressure: it is closed: 1.45–1.6 bar opens: 2.9–3.2 bar ring consolidation: internal diameter is 9.3 mm thickness is 1.8 mm inhaling moment: 5.5 N of m. 16. Valve of low pressure 17. Evaporator ring consolidation on an entrance: internal diameter is 10.8 mm thickness is 1.8 mm at the exit: internal diameter is 17.2 mm thickness is 1.8 mm inhaling moment: 16 N. of m. |
Prevention
Elements of control of the conditioner
1. Hatch of supply of fresh air and
air recirculation 2. External temperature sensor 3. Vacuum amplifier it is intended for supply of fresh air in the hatch and for air recirculation 4. Dashboard air inlet 5. Two-sided valve it is intended for supply of fresh air in the hatch and for air recirculation 6. Delivery fan of fresh air |
7. Panel of the central air inlet and control system 8. Switch of supply of fresh air and mode of recirculation 9. Switch of the air conditioner 10. Control unit of the conditioner 11. Ropes connection on the control unit connections with folding gates 12. Openings for heating of legs 13. Consecutive resistance of the delivery fan |
Prevention
Scheme of an arrangement of components
1. External temperature sensor | 8. Adjusting engine regulates position of the gate of control of temperature (by means of a feedback potentiometer) feedback potentiometer 9. Vacuum block ensures functioning of the air gate retsirkulirouyemogo/fresh air 10. The engine of the fan forcing fresh air 11. Heater together with the evaporator 12. Control unit regulates operation of the delivery fan 13. Switch of low pressure it is intended for ensuring functioning of the cooling system |